Kabeltec

H05V-K | H07V-K | LIY-V

  • Cabled de control
    • 2XSLCHK-J LSOH
    • 2XSLCHK-J 3PLUS / LSOH
    • 2XSLCY-J 3plus transparent/orange
    • 2YSLCY-J / 2YSLCYK-J EMC+ black
    • 2YSLCY-J 3 PLUS EMV
    • FLEX-CY-JB/OB
    • CY-JZ Grey
    • FLEX-CY-JZ POWER
    • FLEX-CY-JZ/OZ
    • Flex-JB yellow
    • FLEX-JB/OB
    • FLEX-JB/OB 450/750V
    • FLEX-JZ POWER
    • FLEX-JZ/OZ
    • FLEX-SY-JB/OB
    • FLEX-SY-JZ/OZ
    • ARCTIC FLEX - JZ
    • PU yellow
    • PU orange
    • PU-CY
    • PU-CY no inner bedding
    • PU-JZ
  • Cables de datos
    • ES-BL-CY paired
    • ES-BL-CY-OZ
    • ES-BL-OZ/JZ
    • Li2YCY / Li2YCYV + negro
    • LI2YCY-PIMF
    • LIYCY
    • LIYCY-CY paired
    • LIYCY-JB 0,6/1kV
    • LIYCY-JZ
    • LIYCY-TP paired
    • LIYCY-UL
    • LIYCY-UL paired
    • LIYY
    • LIYY paired
    • LIYY-UL
    • RE2X(ST)Yv
    • RE2X(ST)Yv
    • RE2X(ST)Yv-PIMF
    • RE2Y(ST)Y
    • RE2Y(ST)Y-PIMF
  • Cables para cadenas portacables
    • EF Data-Cable
    • EF-CY Data-Cable
    • FLEX-EF
    • Flex-EF SC
    • FLEX-EF-CY
    • Flex-EF-CY EA
    • FLEX-PU-EF
    • FLEX-PU-EF-CY
    • INDRAMAT® Feedback
    • INDRAMAT® Power
    • Motor cable for Fanuc-Systems
    • MULTIPLUS-CP
    • MULTIPLUS-CP
    • MULTIPLUS-P
    • MULTIPLUS-P
    • PU-EF (12Y11Y) SC
    • PU-EF Data-Transmission cable
    • PU-EF-CP (12YC11Y) SC
    • PU-EF-CP (TP) Data-Cable
    • PU-EF-CP Data Transmission cable
    • Siemens Servo Feedback
    • Servo Cable for Siemens-Systems
  • Cables aprobados según VDE
    • H03VVH2-F
    • H05BQ-F, H07BQ-F black
    • H05BQ-F/H07BQ-F
    • H05VV5-F (NYSLYO-J)
    • H05VV5-F 4-Approvals
    • H05VVC4V5-K (NYSLCYO-J)
    • H05VVC4V5-K -Approvals
  • Cables según normas internacionales
    • 2- Norm UL/CSA
    • 2-Norm (UL/CSA-CY)
    • AR2V
    • AT-N05V3V3-F
    • AT-N07V3V3-F
    • BS 5308
    • BS 5308 collective screened
    • BS 5308 collective screened
    • BS 5308 SWA amoured
    • BS 5467 XLPE/PVC/AWA/PVC
    • BS 5467 XLPE/PVC/SWA/PVC
    • BS 6724 AWA Single Core
    • BS6724 unarmored Single Core
    • BS6724 XLPE/LSZH/SWA/LSZH
    • CEI 20-22 II
    • DLO 2kV
    • FG16M16/FG16OM16 0,6/1kV (FG7M1 / FG7OM1)
    • FG7OH2R
    • FG16R16/FG16OR 16 0,6/1kV (FG7R/FG7OR)
    • FROH2R
    • FROR
    • FS17 450/750V (N05V-K / N07V-K)
    • H05V2-K | H07V2-K
    • RV-K 0.6/1 kV
    • RZ1-K (AS)
    • SJ
    • SJOOW und SOOW
    • SJT und SVT
    • SJTO und STO
    • SOOW
    • TRAY
    • TRAY CY
    • Type W
    • Type W Singlecore
    • U-1000 R2V
    • UL/CSA Style 1007/1569
    • UL/CSA Style 1015
    • UL/CSA Style 1430/1431
  • Cables de instalación y conductores individuales
    • (N)YM(ST)-J
    • ESUY
    • ESY
    • FLKF/LIFY
    • FLRY
    • H03VV-F
    • H05V-K | H07V-K | LIY-V
    • H05V-U/H07V-U
    • H05V2-K | H07V2-K
    • H05VV-F
    • H07V-R
    • NYM-O / NYM-J
  • Cables de compensación y cables resistentes al calor
    • FEP
    • FEP-Single core
    • FZLSI
    • H05SS-F
    • N2GMH2G-J
    • PTFE-Single cores
    • SID
    • SIF
    • SIF/GL
    • SIFF
    • SIFL/PVC
    • SIFL/PVC
    • SIHF-CU-SI with inner bedding
    • SIHF-CU-SI black
    • SIHF-GLP
    • SIHF-J
    • SIHF-J negro
    • SIHF/PVC
    • SIHF/PVC
  • Cables libres de halógenos
    • (N)HXCH-FE 180 / E30
    • (N)HXCH-FE 180 / E90
    • (N)HXH-FE 180 / E30
    • (N)HXH-FE 180 / E90
    • FLEX-(ST)CH EMC
    • FLEX-CH
    • FLEX-H POWER
    • FLEX-H
    • FLEX-H POWER
    • FLEX-H-JB
    • FLEX-SY-JB/OB
    • H05Z-K und H07Z-K
    • H05VV-F
    • H07RN-F
    • H07ZZ-F
    • J-H(ST)H...Bd
    • J-H(ST)H....Bd
    • JE-H(ST)H...Bd E30
    • JE-H(ST)H...BD E30 red
    • JE-H(ST)H....Bd E90
    • JE-H(ST)H...Bd E90
    • LiHCH (TP)
    • LiHCH
    • LiHCH (TP)
    • LiHH
    • N2XCH
    • N2XH-O/-J
    • NHXMH-J/O
    • NSHXAFOU
    • RD-H(St)H
  • Cables planos, cables para ascensores
    • LIFT 2S
    • LIFT 2S UL
    • LIFT-H
    • LIFT-S
    • LIFT-S UL
    • LSOH FLAT
    • NEO-Flatform (NGFLGÖU)
    • NEO-Flatform (NGFLGÖU)
    • NEO-FLACH-CY
    • NEO-FLACH-CY UL
    • PVC-FLATFORM (H05VVH6-F)
    • PVC-FLAT (H07VVH6-F)
    • PVC-FLAT UL
    • PVC-FLAT-CY
  • Cables para buques
    • FM2XCH
    • FMGSGO
    • FMSGSGO
    • LMGSGO
    • M2XH
    • MGSGO
    • MPRX
    • MPRXCX
    • RFOU
    • TCX(C)
  • Cables de alarma de incendio, cables de telecomunicaciones
    • A-2Y(L)2Y...St III Bd.
    • A-2YF(L)2Y...St III Bd.
    • A-DQ(ZN)B2Y
    • FIREFIT LIH(ST)H FE 180 PH 90
    • FIREFIT LIH(ST)H-TP FE 180 PH 90
    • FIREFIT LIH(ST)H-TP FE 180 PH 90 (Class 1)
    • FIREFIT LIHH FE180/PH 90
    • FIREFIT LIHH - TP FE180/PH 90
    • FIREFIT LIHH - TP FE180/PH 90 (Class 1)
    • I-Y(ST)Y Fire Alarm Cable
    • I-Y(ST)Y...Lg
    • J-2Y(ST)Y...St III Bd
    • J-YY...Bd
    • JE-LIYCY...Bd Si
    • JE-Y(ST)Y...Bd Si
  • Cables de corriente fuerte
    • (N)2XCY FR
    • (N)2XY FR
    • N2XS(F)2Y
    • N2XS2Y
    • N2XSEY
    • N2XSY
    • NA2XS(F)2Y
    • NA2XS2Y
    • NA2XSY
    • NAYCWY
    • NAYY-J
    • NYCWY
    • NYCY
    • NYY-O/-J
  • Cables de góma
    • (N)SHTOU VS YELLOW
    • H01N2-D
    • H05RN-F/H05RR-F
    • H07BN4-F
    • H07RN-F
    • H07RN8-F
    • NEOPREN
    • NSGAFÖU
    • NSHTOU-J
    • NSSHOU / 3E
    • NSSHOU-O/-J
    • TML-O/-J
    • Trommelflex PU-HF
  • Cable de sonido e iluminación
    • SOFTFLEX-JB negro
    • SOFTFLEX-JZ negro
  • Cables coaxiales, cables de bus, cables en forma espiral
    • ASI-BUS PUR / TPE /EPDM
    • BUS-EIB verde KNX
    • BUS-EIB-H green
    • BUS-LD
    • BUS-LD PUR
    • BUS CABLE
    • BUS-LD
    • DEVICE NET THICK THIN
    • DEVICE NET THICK THIN
    • L2 BUS FC LSOH
    • PA-BUS FC libre de halogenos
    • PA-BUS fast connect
    • PA-BUS Black/Blue
    • BUS CABLE
  • Cables especiales
    • FLEX-H-JB 450/750V
    • (N)2XCY FR
    • (N)TSCGEWOEU-F
    • (N)TSCGEWOEU-R
    • (N)TSCGEWOEU-SR
    • (N)TSCGEWOEU-TR
    • (N)TSKCGECWOEU-CH
    • (N)TSKGECWOEU-FN
    • 2XSLCY-J 3plus transparent/orange
    • 2- Norm UL/CSA
    • 2- Norm UL/CSA
    • ES-BL-CY-OZ UV-resistant
    • FLEX-H
    • FLEX-CH
    • FQAR-PG 150/250V
    • FQLQ 450/750V
    • Kabeltec-Battery BQ-F
    • KTECtherm 125
    • LiHCH (TP)
    • LIYCY
    • NTSCGEWOEU-W/3
    • NTSCGEWOEU-W/3E
    • NAYCWY
    • S05VV5-F UL/CSA negro
    • SOFTFLEX-JB negro
    • UL/CSA Style 1015
    • LiHCH (TP)
    • YSLY-O UL Black Ul/CSA
  • Soluciones sistemáticos
  • Technología solar
    • Kabeltec-Battery BQ-F
    • Kabeltec-Battery BQ-F
    • SOLAR H1Z2Z2-K PV1-F TÜV/CE
Sie suchen ein bestimmtes Kabel? Nutzen Sie unsere Kabelsuche.

H05V-K | H07V-K | LIY-V

Conductores individuales de PVC

core
el uso

H05V-K/H07V-K En ambientes interiore secos para la instalación fija y flexible en los sistemas de conmutación y distribución LIY-V. Previsto para el cableado de los equipos de telecomunicaciones para el cableado de los componentes electrónicos en los dispositivos y para el cableado de los sistemas de telecomunicaciones.

Construction
-LIY-V: conductor de CU de hilo fino
- HO5V-K/HO7V-K: conductor de CU desnudo de hilo fino
- Aislamiento de los conductores de PVC
- disponible en varios colores, véase código de color
el material del conductor cobre, desnudo LIYV: cobre, destañado
la clase del conductor Clase 5
el aislamiento de los conductores PVC
la identificación de los conductores aislados
los trenzados
el material de la cubierta exterior PVC
el color para la cubierta disponible en varios colores, véase código de color
tensión nominal [V] H05V-K: 300/500 V H07V-K: 450/750 V LIY-V: 500/900
tensión soportada [V] H05V-K: 2000 V H07V-K: 2500 V LIYV: 2500
la resistencia del conductor
insulation resistance > 20 MΩ x km
la capacidad del corriente
Rayon de courbure minimum pour pose fixe AD mas chicos 8 mm: 4x AD; AD mas grandes 8-12 mm: 5x AD; AD mas grandes 12 mm: 6x AD
Rayon de courbure minimum en mouvement
la temperatura de funcionamiento sujeto min / max [C] -30°C hasta +80°C
la temperatura de funcionamiento movible min / max [C] +5°C hasta +70°C
la temperatura en el conductor maximal
el comportamiento del fuego VDE 0482-332-1-2 y IEC 60332-1
las normas VDE 0281-3
Cable
The listed values (e.g.: diameters, weights, etc.) are non-binding and without guarantee.
If the exact values are required then these have to be requested expressly in writing with the inquiry and/or order.

Nr Article   Conducteur x Section transversale awg   Diamètre extérieur ca. mm   Poids cuivre kg/100m   Poids kg/100m
33..0014   1 x 0.14   1.00   0.14   0.21
33..0025   1 x 0.25   1.30   0.25   0.26
33..0034   1 x 0.34   1.40   0.33   0.40
33..0038   1 x 0.38   1.60   0.37   0.50
333..0005   1 x 0.05   0.70   0.06   0.13
333..0008   1 x 0.08   0.80   0.08   0.16
333..0014   1 x 0.14   1.10   0.14   0.21
333..0025
  1 x 0.25   1.30   0.24   0.42
333..0038   1 x 0.38   1.70   0.38   0.66
34..0050   1 x 0.50   2.10   0.48   1.00
34..0075   1 x 0.75   2.30   0.72   1.20
34..0100   1 x 1   2.50   0.96   1.40
33..0050   1 x 0.50   1.80   0.48   0.80
33..0075   1 x 0.75   2.00   0.72   1.20
33..0100   1 x 1   2.10   0.96   1.80
333..0050   1 x 0.50   2.00   0.48   0.89
333..0075   1 x 0.75   2.20   0.72   1.18
333..0100   1 x 1   2.50   0.96   1.54
35..0150   1 x 1.50   3.00   1.44   2.10
33..0150   1 x 1.50   2.60   1.44   2.20
333..0150   1 x 1.50   2.90   1.44   2.14
35..0250   1 x 2.50   3.70   2.40   3.30
33..0250   1 x 2.50   3.20   2.40   3.70
333..0250   1 x 2.50   3.60   2.40   3.37
35..0400   1 x 4   4.20   3.84   5.00
35..0600   1 x 6   4.80   5.80   6.50
35..1000   1 x 10   6.20   9.60   12.00
35..1600   1 x 16   7.70   15.40   18.00
35..2500   1 x 25   9.20   24.00   26.00
35..3500   1 x 35   11.50   33.60   36.00
35..5000   1 x 50   12.50   48.00   51.50
35..7000   1 x 70   15.00   67.20   71.00
35..9500   1 x 95   16.00   91.20   94.00
35..12000
  1 x 120   18.50   115.20   118.00
35..15000   1 x 150   20.00   144.00   160.00